Concrete pump calculator

Use our concrete calculator to calculate the exact volume of concrete you need for your job.

Sizing a Pump

If you are unsure on how to calculate just click on the 3 boxes and enter your length, width and height. The calculator will then multiply the numbers and provide you with the appropriate equation. Please leave this field empty. We can supply any type of ready mix concrete that you specify and if you require a concrete pumping service, see our concrete pump section.

Here's What People Are Saying. Mini Mix. Very helpfull! Pumped Concrete! What a great service! Concrete Volume Calculator. Make an enquiry. Our Services Concrete Mixes We can supply any type of ready mix concrete that you specify and if you require a concrete pumping service, see our concrete pump section.

Concrete Pumps We supply concrete pumps for those difficult to access places. Mini Mixers Mini Mix lorries for tight access. Same size as a 6 yard skip lorry. Why Choose Ready Mix Concrete? DaveWatford Mini Mix. MasonWelwyn Garden City Very helpfull! Flaharty GroundworksHemel Hempstead What a great service!During this COVID pandemic, Pentair global operations and supply teams are working diligently to help ensure our valued customers are getting the best possible service and delivery during this time.

Despite our efforts, shipping delays may occur. Our customer service teams are available and ready to support you through this dynamic situation. As part of its separation into a new pure play water company, a new Pentair website has launched. Please visit the new Pentair. By submitting your information, you confirm that you agree to the storing and processing of your personal information by Pentair Aquatic Eco-Systems, Inc. Enter the total horizontal pipe length feet for your system.

Select nominal pipe diameter inches using the pull-down menu. Enter total pumping lift or height feet water is pumped vertically.

Long-distance concrete pumping: does your pump meet your job’s pressure requirements? [CALCULATOR]

Enter any misc. Enter the number of pipe fittings elbows, tees. Select a pump based on flowrate and total head loss requirements. Filtration Biological Filtration Biomedia Bioreactors. Specialty Protein Skimmers. Liners Pond Liners Tank Liners. Sign Up for Special Offers By submitting your information, you confirm that you agree to the storing and processing of your personal information by Pentair Aquatic Eco-Systems, Inc.

Sign Up. Email Address Send Me Offers. Stay Connected. All rights reserved. Javascript is required to view this site.Dear Visitor, This website uses third-party cookies and applications in order to optimise the web presentation. This involves:. The main purpose of this is to adapt our offers to our customers' preferences, and also to make your visit to the website as convenient as possible.

Do you agree to the use of cookies and the processing of your personal data in connection with this? You can find further information on the use of cookies in our Data Protection Declaration. These cookies include, for instance, the saving of login data, the shopping basket and the language selection by so-called session cookies deleted when you close your browser. Strictly necessary cookies are therefore essential for the basic functionality of our website. We use these cookies to analyse visits to the website in order to optimise the functionality and customer experience of our website.

Locations Germany Worldwide. News Current Archive Newsletter Events. Time between the first addition of water for making the concrete and the point in time at wich the concrete is full set.

Fresh concrete temperature used to determine the end of setting tE. Temperature of fresh concrete just after placing between the formwork. Dead weight divided by the volume of the fresh concrete after compaction. Please note that in any case the DIN and its regulations are valid. Cookies and Applications X.

This involves: the optimal functionality of our website and a tailored design by analysing visits to the website The main purpose of this is to adapt our offers to our customers' preferences, and also to make your visit to the website as convenient as possible. Request further information. Yes, I agree to the use of non-essential cookies. Assumptions: Outside temperature has no influence on concrete temperature.

Measure of the deformability and flowability of the fresh concrete.Take a look at the various pond calculators below. Use the volume calculator to calculate the volume of a pond in litres or gallons. The liner calculator will work out the size of liner required based on the ponds dimensions. If you need to know how much water should to be pumped by a pump then use the pump calculator.

The cost calculator will tell you the electrical cost of running your pond monthly or annually, you can also use this calculator for individual components or to compare the cost of running different components. Calculate the volume of a pond in litres or gallons. If the pond is not exactly recangular or circular use average dimensions.

Calculate the size of liner required. Enter the maximum dimensions of the pond. Also enter the amount of overlap required per side of the liner if any.

CONCRETE CALCULATOR

Calculate the minimum amount of water that the pump is required to pump in GPH gallons per hour and LPH litres per hour. Calculate the volume of water that the pump must be able to cycle every hour. However, static head and losses also need to be taken into consideration. If the pump is carrying the water to a height above the ponds surface to a waterfall for example, then it will encounter "static head".

Static head is the vertical distance the water is raised. The higher the water is carried the greater the static head. Other losses include friction in the hose, know as "friction head".

For every 10 feet of hose the water must travel through is approximately equivalent to 1 foot of static head. As the static head increases the flow rate of the pump will decrease. Therefore when choosing a pump it is important to make sure that the pump can deliver the required flow at the static head it will encounter. The specifications of a pump will normally display a chart representing the flow rate at different heights static head.

Calculate the monthly and yearly electrical cost of running your pond or an individual component. The "Total Power Usage" is the total sum of power used by all the electrical devises. Make a list of all the devises that are utilised by the pond continuously and note their power rating.The Concrete Calculator estimates the volume and weight of concrete necessary to cover a given area. Purchasing slightly more concrete than the estimated result can reduce the probability of having insufficient concrete.

Related Volume Calculator. Concrete is a material comprised of a number of coarse aggregates particulate materials such as sand, gravel, crushed stone, and slag bonded with cement.

Cement is a substance that is used to bind materials, such as aggregate, by adhering to said materials, then hardening over time.

While there are many types of cement, Portland cement is the most commonly used cement, and is an ingredient in concrete, mortar, and plasters. Concrete can be purchased in multiple forms, including in 60 or pound bags, or delivered in large amounts by specialized concrete mixer trucks.

Proper mixing is essential for the production of strong, uniform concrete. It involves mixing water, aggregate, cement, and any desired additives. Production of concrete is time-sensitive, and the concrete must be placed before it hardens since it is usually prepared as a viscous fluid.

Some concretes are even designed to harden more quickly for applications that require rapid set time. Alternatively, in some factory settings, concrete is mixed into dryer forms to manufacture precast concrete products such as concrete walls. The process of concrete hardening once it has been placed is called curing, and is a slow process.

Long-distance concrete pumping: does your pump meet your job’s pressure requirements? [CALCULATOR]

Ensuring that the concrete is damp can increase the strength of the concrete during the early stages of curing. This is achieved through techniques such as spraying concrete slabs with compounds that create a film over the concrete that retains water, as well as ponding, where concrete is submerged in water and wrapped in plastic.

Financial Fitness and Health Math Other. Outer Diameter d 1.On the typical concrete pour, your goal is to place the concrete as close as possible to its final destination—not only to save hauling time and boost productivity, but also to avoid overhandling the concrete.

concrete pump calculator

But on many concrete jobs, the ready-mix truck can't gain access to the work site. When you're placing a stamped concrete patio in a fenced backyard, a decorative floor inside in an enclosed building or working on a high-rise building, you must find another way to move the concrete from the truck to the point of placement.

Pumping is an efficient, reliable and economical means of placing concrete, and sometimes the only way of getting concrete into certain locations. Other times, simply the ease and speed of pumping concrete make it the most economical method of concrete placement.

In the end, the convenience of easy access for truck mixers must be weighed against the desirability of locating the pump closer to the placement point. When concrete is pumped, it is separated from the pump line walls by a lubricating layer of water, cement and sand. Naturally, the concrete mix must be suitable for its particular application, but it must also contain enough water for the mix to move easily through the reducers, bends and hoses found in most basic pipeline setups.

Pump primers can greatly reduce issues associated with pumping concrete and help pumping lines last longer. It is important to have all concrete mixes specified as "pumpable" prior to any concrete pours. There are mixes that do not pump at all or cause the pump lines to clog. This can cause big problems if you have 8 trucks arriving on the job ready to discharge concrete.

concrete pump calculator

See more about removing blockages. In order to optimize the concrete pumping operation, the most efficient configuration of the system must be determined. The correct line pressure must be determined to move concrete at a specified rate of flow through a pipeline of a particular length and diameter. The major factors affecting pipeline pressure are:. In addition, a number of other factors must be taken into account when determining line pressure, including:.

Larger-diameter pipelines require less pumping pressure than smaller-diameter pipes. However, there are disadvantages to using the larger conduits, such as increased blocking, bracing and labor needed. Regarding the concrete mix in relation to line diameter, the maximum size of aggregate should be no larger than one-third of the diameter of the line, according to ACI standards. Concrete being pumped through a line experiences friction with the internal wall of the pipeline.

The longer the line, the more friction encountered. For longer pumping distances, the use of smooth-walled steel pipe can lower the resistance. The length of hose used at the end of the pipeline adds to the overall line length as well. The farther or higher the concrete needs to go, the more pressure it will take to get it there. If there is a long horizontal distance to cover, one option is to use two lines and two pumps, with the first pump feeding into the hopper of the second pump.

This method may be more efficient than a single, long-distance line. Because of resistance encountered with changes in direction, the pipeline layout should be designed with the least number of bends possible. Resistance will also increase if there is a reduction in pipe diameter along the path the concrete travels.

concrete pump calculator

Whenever possible, the same diameter line should be used. However, if reducers are needed, longer reducers will cause less resistance.Contact your MEVA representative for guidance in your territory if you want to use it outside Europe.

Formwork Pressure Calculator. The reshoring calculator backpropping calculator is based on the guidelines set out in the DBV German Concrete and Building Technology Association memorandum on concrete formwork and stripping timelines. By using the MEVA calculator tools, the user accepts the following terms and conditions of use:. They have been thoroughly tested before being made available on the MEVA website and in the App-Stores for iOS and Android applications, yet no guarantee of freedom from error can be given.

The results calculated with and obtained from the MEVA calculation tools must be carefully cross-checked by the user. Until further notice, the MEVA calculation tools shall be made available without charge and — insofar as legally permissible — to the express exclusion of any and all warranty rights. Liability is excluded for all cases of damage to life, health and limb resulting from gross negligence or malicious neglect of duty by MEVA or its subcontractors. MEVA endeavours to keep the MEVA website and the application free of viruses but cannot guarantee that these will always be free of viruses.

Users shall ensure and install adequate safety precautions, virus scanners etc. MEVA shall be liable for injury solely within the bounds of mandatory statutory provisions.

For any other damage, MEVA shall only be liable in cases of gross negligence and malicious intent. MEVA shall not be liable for consequential damages, financial losses and data loss. The information contained on the MEVA website and in the MEVA application, including the calculation tools are the intellectual property of MEVA and may not be altered, supplemented, sold, rented or otherwise commercially exploited, in any manner whatever, without the prior written consent of MEVA.

If any provision s of these terms and conditions of use should be or become inoperative, whether in whole or in part, or if the terms and conditions are found to contain a loophole, this shall have no bearing upon the validity of the remaining terms and conditions. Any wholly or partially inoperative provisions, or loopholes, are hereby deemed to have been superseded by an appropriate and effective new provision which — to the extent legally possible — fulfils or most closely approximates to the originally intended legal and business purpose.

Only German law shall apply. Contact: Please e-mail any questions concerning these terms and conditions of use or the utilisation of the calculation tools to the following e-mail address: info meva.

Concrete Yardage Calculator

You are facing a difficult concrete pour, for instance when building very high walls and wish to be on the safe side when it comes to concrete setting time?

SolidCheck is a portable measuring device that enables you to determine the exact setting time of the concrete actually batched to your site. Knowing the exact setting time allows you to utilise the concrete load capacity of your formwork fully and safely. MEVA offers this innovative ultrasonic measuring technology as a service to your site, including a trained professional operator to conduct the measurement with you. Search term.

Home Web Services Concrete pressure calculator. Download the Calculator with american units Formwork Pressure Calculator. Your browser does not support cookies! Please activate cookies in your browser settings.

Then refresh this page. By using the MEVA calculator tools, the user accepts the following terms and conditions of use: 1. Concrete Setting Time. Please enter your e-mail.


Comments

Add a Comment

Your email address will not be published. Required fields are marked *